Easy Returns No restocking fee for 90 days. Need replacement parts for this unit? View Replacement Parts. Manuals 2. Speak with a real person who will go out of the way to help!

Call or Text Text Call Have suggestions or feedback about this page? Let us know below! Submit Cancel. Thank you for your feedback! Space-age technology for oil-fired heating systems. Heating oil is converted into gas using the thermodynamic premixing principle, which is based on knowledge gained from aviation and space flight. The result is perfect combustion with a blue flame. If it is higher than this, the boiler should be shut down and the thermostat settings checked.

If the problem persists, call a technician. The pressure should not fall below 1 bar. Unscrew the cover and press the restart button using a pen or a similar pointed object, then replace the cover. If the problem persists, turn the boiler off and call a technician. DE IT Water from the safety valve may be extremely hot and cause very severe burns.

If the oil or gas burner is not working, turn off the power to the boiler using the external isolator before resetting the safety thermostat on the control panel.

If the problem persists, please contact your installer. ES Manual reset safety thermostat ACV oil burners To make sure your system works correctly, please have it serviced every year by a qualified technician before the heating season. IT Starting the burner: In normal operation, the burner starts automatically as soon as the boiler drops below the temperature set point.

Upon receipt and after unpacking, check the equipment for transport damage. It is protected from heat by a blanket insulation. The boiler uses a single phase supply at V - 50 Hz. A mains isolator with 6A mcb 5A fuse must be fitted outside the boiler to allow the power to be shut off during servicing and before any repairs are carried out. Blue Br. Brown Bk. Black G. Grey Gr. Green Or. Orange V. The resulting sludge is then deposited in the boiler exchanger.

The combination of carbonates and carbon dioxide in the water results in the formation of scale on the hot surfaces of the installation, including those of the boiler exchanger. These deposits in the heat exchanger reduce the water flow rate and thermally insulate the exchange surfaces, which is likely to damage them.

Sources of oxygen and carbonates in the heating circuit The primary circuit is a closed circuit; the water it contains is therefore isolated from the mains water.

When maintaining the system or filling up the circuit, water renewal results in the addition of oxygen and carbonates in the primary circuit. The larger the water volume in the system, the larger the addition. Hydraulic components without an oxygen barrier PE pipes and connections admit oxygen into the system.

Control the heating water parameters - In addition to the oxygen and the water hardness, other parameters of the water must be checked.

Clean the existing system before installing a new boiler - Before the system is filled, it must be cleaned in accordance with standard EN Chemical cleaning agents can be used. Limit the fill frequency - Limit fill operations. In order to check the quantity of water that has been added into the system, a water meter can be installed on the filling line of the primary circuit. Limit the presence of oxygen and sludge in the water - A deaerator on the boiler flow line combined with a dirt separator upstream of the boiler must be installed according to the manufacturer's instructions.

Accessibility The boiler room must be large enough to allow good access to the boiler. The following minimum distances are required around the boiler: mm in front, mm to the sides, mm behind and mm above.

The tables below give the values defined according to Belgian regulations. Given that regulations vary from one country to the next, these tables are given for information only. Each installer must ensure that boiler room ventilation complies with current regulations. C53 : Connection to separate ducts for the supply of combustion air and for venting the combustion products; these ducts may end in zones with different pressure levels. B23P : Connection to an exhaust system of the combustion products designed to operate with positive pressure.

Prohibited in Belgium. C43 : Connection by two ducts to a collective duct system serving more than one appliance; this system of collective ducts features two ducts connected to a terminal unit that simultaneously takes in fresh air for the burner and discharges the combustion products outside through openings that are either concentric or close enough together to be subjected to similar wind conditions.

Due to the high efficiency of our boilers, the flue gases are released at low temperature. As a result, there is a risk of condensation of the flue gases, which could damage some chimney constructions; to avoid this risk, it is strongly recommended to line the chimney. To prevent condensates to flow back into the boiler, we strongly advise to install a condensates collector.

Please contact your installer for more information. Connection type Models Burners B23 B23P C13 C33 NL C33 ES : Connection by pipes with horizontal terminals that simultaneously take in combustion air for the burner and discharge combustion products outside through openings that are either concentric or close enough together to be subjected to similar wind conditions. Pressure reducer 3. Temperature control valve 4.

Hot water circulator optional 5. Non-return valve 6. Hot water expansion tank as standard on Pro Pack, 2 litres 7. SC Sales sheet Page 1 table. Direct Spark Ignition is standard on ail units. AH Wayne gas burners include die cast aluminum housings for prcise alignment of parts and a machined cast iron venturi for superior mixing of gas and air. Universal mounting flange adapts to any appliance. Ail models factory-wired and test-fired. Available in 8" air tube length only 7" maximum insertion.